Skip to main content

Table 2 Literature summary of intraoperative clip adjustment rates after ICG-VA

From: The role of intraoperative videoangiography in aneurysm surgery—a comparative study from a tertiary care hospital

Authors and year No. of patients undergoing ICG-VA Clip adjustment rate (%) Aneurysm remnants on intra-op/post-op DSA (%)
Raabe et al., 2003 [1] 14 7.1 NA
Raabe et al., 2005 [2] 114 9 NA
Imizu et al., 2008 [9] 13 38 61
Li et al., 2009 [10] 120 4.6 NA
Ma et al., 2009 [11] 45 4.4 6.7
Dashti et al., 2009 [12] 190 12 6
Jing et al., 2010 [13] 42 5 2
Wang et al., 2010 [14] 129 2 NA
Fischer et al., 2010 [15] 50 10 6
Gruber et al., 2011 [16] 104 6.7 NA
Oda et al., 2011 [17] 39 10 10
Washington et al., 2013 [7] 49 4.1 6.1
Özgiray et al., 2013 [18] 109 1.8 3.6
Moon et al., 2013 [19] 127 6.3 4.7
Roessler et al., 2014 [4] 232 9.1 4.5
Hardesty et al.,2014 [8] 79 5 NA
Current study 332 6.59 NA
  1. NA not available